Drying removes a liquid, usually water, from a solid by evaporation, and it is a full unit in most pharmaceutical engineering syllabi. Two ideas carry most of the marks: the basis on which moisture is reported, and the shape of the drying-rate curve.
Wet basis or dry basis? Moisture on a wet basis is the mass of water divided by the mass of the wet solid. On a dry basis it is the mass of water divided by the mass of bone-dry solid, and drying calculations are done on a dry basis because the dry solid does not change.
The drying curve. After a short warming-up stage, wet material dries at a constant rate while its surface stays saturated, like a free water surface. Once the moisture falls to the critical moisture content, water has to move from inside the solid, the rate falls, and the falling-rate period continues towards the equilibrium moisture content set by the humidity of the air.
Fictional readings. A batch of 50 kg of wet granules holds 25 percent moisture on a wet basis and must be dried to 5 percent. The tray area is 4 m², the constant drying rate is 1.5 kg of water per m² per hour, the critical moisture content is 0.15 kg water per kg dry solid, and equilibrium moisture is taken as zero.
| Step | Working | Result |
|---|
| Dry solid | 50 × 0.75 | 37.5 kg |
| Final batch mass | 37.5 ÷ 0.95 | 39.47 kg |
| Water removed | 50 − 39.47 | 10.53 kg |
| Initial moisture, dry basis | 12.5 ÷ 37.5 | 0.333 kg/kg |
| Final moisture, dry basis | 1.97 ÷ 37.5 | 0.0526 kg/kg |
| Constant-rate time | 37.5 × (0.333 − 0.15) ÷ (4 × 1.5) | 1.15 h |
| Falling-rate time, linear rate assumed | (37.5 × 0.15 ÷ 6) × ln(0.15 ÷ 0.0526) | 0.98 h |
| Total drying time | 1.15 + 0.98 | about 2.13 h |
Two points examiners like to see: the falling-rate period takes almost as long as the constant-rate period although it removes far less water, and a lower critical moisture content (thinner beds, smaller granules) shortens the whole run. On the equipment side, learn the tray dryer, fluidised bed dryer, spray dryer, drum dryer, vacuum dryer and freeze dryer, each with one reason it suits a particular product, such as the freeze dryer for heat-sensitive biological products.
Practice maths for exams only. Not clinical guidance; always follow your local protocol and prescriber.